Equipments - Multi Frac Split

Use the Multi_Frac_Split to split an inlet stream into two to five outlet streams.

What do you want to see?

 

Data Description

Data Unit Description
Set Item Type Native
Equipment Properties First Outlet Fraction Fraction or Percent Fraction Fraction of the total inlet flow in the first outlet flow.
Second Outlet Fraction Fraction or Percent Fraction Fraction of the total inlet flow in the second outlet flow.
Third Outlet Fraction Mass FlowFraction or Percent Fraction Fraction of the total inlet flow in the third outlet flow.
Fourth Outlet Fraction Fraction or Percent Fraction Fraction of the total inlet flow in the fourth outlet flow.
Fifth Outlet Fraction Fraction or Percent Fraction Fraction of the total inlet flow in the fifth outlet flow.
Top of Page

Equipment Properties

Top of Page

Example of using equipment

Top of Page

Method&Equations

The model determines the flows in the outlets using the flow fractions you specify.

The fraction of the inlet stream flow is sent to each of the outlet streams. The remaining flow is equally distributed to the outlet streams whose fractions have not been set.

Top of Page

Warnings

Zero flow entering!

Fractions don't add to 1.0!

Top of Page

Errors

Missing Stream(s)!

Top of Page