The WL Oxidizer model is used to simulate the oxidization of sulfur from H2S to S2O3-- with bubble aeration.
|
What do you want to see?
|
|
|
Data |
Unit |
Description |
|
Set |
Item |
Type |
Native |
|
Equipment Properties |
Excess Oxygen |
Fraction or Percentage |
Fraction |
The amount of oxygen in excess on the basis of the consumed oxygen
|
|
WL Outlet Temp |
Temperature |
F |
The white liquor outlet temperature
|
The inlet air is mixed with the inlet white liquor, the reaction takes place:
2H2S + 2O2 -> H2O + S2O3-- + 2H+
The heat of reaction determine a temperature rise, the economizer inlet water cools the reaction mixture to the user specified temperature.
The reaction mixture is flashed gasses are living the equipment trough the Vent stream, and the liquid trough the Liquor_Out stream.
Being a composite item – each component may call its warnings.